    BET Surface Area Analyzer
    The BET Surface Area Analyzer work principle isothermal physical international general adsorption static volumetric method,the automatic control of the whole computer, without the need for manual monitoring.
    read more
  • Surface Area Analyzer
    Surface Area Analyzer With One Testing Position
    Best Price For Surface Area Analyzer For Powder Materials Research SPECIFICATIONS The TOB-BETSpecific Surface Area Instrumentis used for Battery materials, magnetic materials, catalyst, adsorbent, cement, ceramic raw materials, metallurgical raw materials, carbon, silica, inorganic materials, coatings, abrasive, nano materials, medicine powder, rare earth, porous material, composite material powder and granular material specific surface area measurement.industry, building materials, coatings, abrasive and other industries. Model Specific Surface Area Tester  TOB-BET-01 Voltage supply AC 110V/220V  50HZ/60HZ±10% Power 300W Warranty One year limited warranty with lifetime support  Technical principle Dynamic nitrogen adsorption surface area tester,  using gas chromatography, low temperature adsorption principle Measuring range 0.1m2/g~3500 m2/g Measure time 5min/sample, Can test one sample every time Measuring accuracy < ±1% Testing method Single point test, contrast test, multi point (BET) analysis. Dimension(L*W*H) 700*360*710mm  Email : tob.amy@tobmachine.com  Skype : amywangbest86  Whatsapp/Phone number : +86 181 2071 5609
    read more
  • Bet Surface Area Analyzer
    Surface Area Analyzer With Two Testing Position
    The TOB-BETSpecific Surface Area Instrumentis used for Battery materials.
    read more
  • Specific Surface Area Instrument
    Surface Area Analyzer With Four Testing Position
    The TOB-BETSpecific Surface Area Instrumentis used for Battery materials.
    read more
  • Bet Surface Area Analyzer
    Surface Area Analyzer With Surface area ≥ 0.01m2/g
    Bet Surface Area Analyzer With Testing Range ≥ 0.01m2/g SPECIFICATIONS Power Voltage: 100V~220V ± 10V  Frequency: 50/60Hz Maximum power: 300W Connection: grounding, single-phase power socket   Physical properties Length: 61cm (24.0 inches) Width: 36cm (14.2 inches) Height: 69cm (27.2inches) Weight: 49kg (108.0 lbs) Accessories weight: 31kg (68.3 lbs) Installation requirements (L * W) 100 * 60cm (not including space computers taking up)   Work environment Temperature: 20 ℃ -28 ℃ Maximum relative humidity: 70%   Technical Parameters    Test principal: Continuous Flow Chromatography method, Low temperature nitrogen adsorption Test methods: Direct Comparison method  Gas: mixed gas of high purity nitrogen and helium (The proportion of nitrogen and helium is 3/7; and gas purity is 99.999%). Flow control: automatic control program, P / Po 0.05 - 0.35, control accuracy error ≤ 0.5%;  Measuring range: Surface area ≥ 0.01m2/g, no upper limits;   Sample NO:  one standard sample and 3 samples tested    Test Efficiency: Direct comparison measures specific surface area: 15 minutes for three samples Repeatability Accuracy:  ≤ ±1 % Data acquisition: high-precision data acquisition and processing chip, high anti-interference ability. Data processing: WINDOWS-compatible data processing software, completely green without installing, providing multi-mode data analysis, graphical processing interface, real-time monitoring experiment, simple operation. Control system: The entire testing process is completely automatic. With large volume dewar and liquid nitrogen surface control technology, the whole experiment don’t need add liquid nitrogen.  Email : tob.amy@tobmachine.com  Skype : amywangbest86  Whatsapp/Phone number : +86 181 2071 5609
    read more
  • China Leading Surface Area and Pore Size Analyzer Manufacturer
    Surface Area and Pore Size Analyzer
    Surface Area and Pore Size Analyzer For Powder Material Research SPECIFICATIONS Power Voltage: 100V~220V ± 10V  Frequency: 50/60Hz Maximum power: 300W Connection: grounding, single-phase power socket Physical properties Length: 60cm (23.6 inches) Width: 48cm (18.9 inches)   Height: 74cm (29.1 inches) Weight: 60kg (132.3 lbs) Accessories Weight: 30kg (66.1 lbs )  Installation requirements (L * W) 100 * 60cm (not including space computers taking up) Functions  ● Surface area measurement: BET surface area (Single-point and multi-point), Langmuir surface area, T-plot method outer surface area,  T-plot method the total inner surface area of microporous, BJH adsorption cumulative surface area of the total pore, BJH desorption cumulative surface area of the total pore ● Determination of pore volume: Single point total pore volume,BJH adsorption cumulative total pore volume    BJH desorption cumulative total pore volume    T-plot method the total pore volume of micropore ● Determination of average pore size:    Adsorption average pore diameter   BJH adsorption average pore diameter   BJH desorption average pore diameter   The most frequency pore ● Pore size distribution:   BJH adsorption and desorption differential pore size distribution (dV / Dr-D) and (dV / dlogD-D)   BJH adsorption and desorption integral distribution (or cumulative distribution)   MP method micropore distribution Technical Parameters Test principle: the static volumetric method, gas adsorption; Analysis Models: BET, Langmuir, BJH, t-plot, DR, MP and NLDFT; Measuring range: surface area ≥ 0.005M2/g, no upper limit; pore size 2 _ 500nm; pore volume 0.0001cc/g, no upper limit; Sorption gas: N2 (high purity); Ar, Kr, CO2, etc. available Analysis No: Two independent analysis ports  Degassing stations: Two Sample Type: powders, granules, fibers, flakes and other materials  Sensor:Two sensors, 0_1000 torr P.S (0_133kpa);  Test Efficiency: multi-point BET surface area _12 minutes per sample; Determination pore size distribution from adsorption isotherms _1.5h per sample;  Determination pore size distribution from adsorption and desorption isotherms _3.5 h per sample. Nitrogen Partial Pressure: P/Po 4×10-5 _ 0.998, the minimum resolvable relative pressure  5 × 10-5 Ultimate vacuum: 4.0 × 10-2Pa(3×10-4  torr) Pressure Accuracy: ≤ ± 0.15% (F.S) Repeatability accuracy: surface area ≤ ±1.0 % (surface area);  ≤2nm (pore size) Operation Mode: Automatic  Email : tob.amy@tobmachine.com  Skype : amywangbest86  Whatsapp/Phone number : +86 181 2071 5609