welcome to XIAMEN TOB NEW ENERGY TECHNOLOGY Co., LTD..
  • English
  • Russian
  • f
  • i
  • y
  • t
  • p
battery machine and materials solution
Products

Hot Products


Electrochemical Workstation
加载中...

Single Channel Electrochemical Workstation Potentiostat Galvanostat for Battery Test

Electrochemical workstation is a general potentiostat galvanostat FRA designed for general purpose electrochemical measurements.
  • Brand:

    TOB NEW ENERGY
  • item no.:

    TOB-CS Series
  • order(moq):

    1set
  • Payment:

    L/C,T/T
  • product origin:

    China
  • shipping port:

    XIAMEN
Product Detail

Single Channel Electrochemical Workstation Potentiostat Galvanostat for Battery Test


SPECIFICATIONS


CS electrochemical workstation (potentiostat / galvanostat) contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat and a galvanostat. With high performance in stability and accuracy with advanced hardware and well-functioned software, it is a comprehensive research platform for corrosion, batteries, electrochemical analysis, sensor, life science and environmental chemistry etc.

Applications
(1) Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation, etc.
(2) Electrochemical analysis and sensor;  
(3) New energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors), advanced functional materials, photoelectronic materials;
(4)Corrosion study of metals in water, concrete and soil etc;
(5) Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.


Specifications

Support 2-, 3- or 4-electrode system

Potential control range: ±10V

Current control range: ±2A

Potential control accuracy: 0.1%×full range±1mV

Current control accuracy: 0.1%×full range

Potential resolution: 10μV (>100Hz),3μV (<10Hz)

Current sensitivity:1pA

Rise time: <1μS (<10mA), <10μS (<2A)

Reference electrode input impedance:1012Ω||20pF

Current range: 2nA~2A, 10 ranges

Compliance voltage: ±21V

Maximum current output: 2A

CV and LSV scan rate : 0.001mV~10,000V/s

CA and CC pulse width: 0.0001~65,000s

Current increment during scan: 1mA@1A/ms

Potential increment during scan: 0.076mV@1V/ms

SWV frequency: 0.001~100 kHz

DPV and NPV pulse width: 0.0001~1000s

AD data acquisition:16bit@1 MHz,20bit@1 kHz

DA Resolution:16bit, setup time:1μs

Minimum potential increment in CV: 0.075mV

IMP frequency: 10μHz~1MHz

Low-pass filters: Covering 8-decade

Potential and current range: Automatic

PC and O/S requirement

 Interface: USB 2.0

Operating System: 

Windows 2000/NT/XP/ win7/win8/win10

Weight / Measurements

Net weight: 6.5kg Gross weight: 10kg

Instrument size: 36.5 x 30.5 x16cm; After package: 52.5 x 37.5x 22.5cm


Electrochemical Impedance Spectroscopy(EIS)

Signal generator

Frequency range:10μHz~1MHz

AC amplitude:1mV~2500mV

DC Bias:-10~+10V

Output impedance:50Ω

Waveform: sine wave, triangular wave and square wave

Wave distortion:<1%

Scanning mode: logarithmic/linear, increase/decrease

Signal analyzer

Integral time:minimum:10ms or the longest time of a cycle

Maximum:106 cycles or 105s

Measurement delay:0~105s

DC offset compensation

Potential automatic compensation range:-10V~+10V

Current compensation range:-1A~+1A

Bandwidth: 8-decade frequency range, automatic and manual setting


Technical advantages

1. Impedance (EIS)
CS potentiostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.). It can also be used to obtain Mott-Schottky curve and differential capacitance curve. During test, the software can display real-time open circuit potential(OCP) without entering.
Electrochemical Workstation

2. Polarization curve

Polarization curve / Tafel plot can be obtained. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material’s pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material’s anti-corrosion ability and inhibitors.


3. Voltammetry

It can do the following experiments: Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV), Staircase Cyclic Voltammetry(SCV), Square wave voltammetry(SWV), Differential Pulse Voltammetry(DPV), Normal Pulse Voltammetry(NPV), AC voltammetry(ACV), Stripping voltammetry etc. It integrates calculation of peak area, peak current and standard curve analysis.

Electrochemical Workstation

4. Electrochemical Noise
With high-resistance follower and zero-resistance ammeter, it measures the natural potential/current fluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Through noise spectrum, we can evaluate the inducement, growth and death of metastable pitting and crack. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.


5. Full floating measurement

CS workstation uses full-floating working electrode. It can be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)


6. User-defined methods

CS workstation supports user-defined combination measurements. The user can set cyclic  timing measurements of an electrochemical method or several methods. 
We are able to provide API functions and development examples, which facilitates some users’ requirements for secondary development and self-defined measurements.


Techniques

TOB-CS150

TOB-CS300

TOB-CS310

TOB-CS350

Stable polarization

Open Circuit Potential (OCP)

Potentiostatic (I-T curve)

Galvanostatic

Potentiodynamic(Tafel plot)

Galvanodynamic

Transient polarization

Multi-Potential Steps

Multi-Current Steps

Potential Stair-Step (VSTEP)

Galvanic Stair-Step (ISTEP)

Chrono methods

Chronopotentiometry (CP)


Chronoamperometry (CA)


Chronocoulometry (CC)


Voltammetry

Cyclic Voltammetry (CV)

Linear Sweep Voltammetry (LSV)

Staircase Voltammetry (SCV) #



Square wave voltammetry (SWV) #



Differential Pulse Voltammetry (DPV)#



Normal Pulse Voltammetry (NPV)#



Differential Normal Pulse Voltammetry(DNPV)#



AC voltammetry (ACV) #



2nd Harmonic A.C.Voltammetry (SHACV)



Amperometry

Differential Pulse Amperometry (DPA)




Double Differential Pulse Amperometry (DDPA)




Triple Pulse Amperometry (TPA)




Integrated Pulse Amperometric Detection (IPAD)




EIS

EIS vs Frequency (IMP)



EIS vs Time (IMPT)



EIS vs Potential (IMPE)(Mott-Schottky)



Corrosion test

Electrochemical Potentiokinetic Reactivation(EPR)

Electrochemical Noise(EN)

Zero resistance Ammeter(ZRA)

Battery test

Battery charge and discharge

Galvanostatic charge and discharge(GCD)

Extensions

Data Logger

Electrochemical stripping/deposition


Bulk electrolysis with Coulometry (BE)


Product Display


Electrochemical Workstation

Electrochemical Workstation

Electrochemical Workstation

Electrochemical Workstation


 Email : tob.amy@tobmachine.com

 Skype :amywangbest86

 Whatsapp/Phone number :+86 181 2071 5609

Send a Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

our works
related products
Electrochemical Workstation
Multichannel Potentiostat Galvanostat Electrochemical Workstation
TOB-CS-3 Multichannel potentiostat/ galvanostat/EIS is a versatile instrument offering 8 slots. High current/voltage: Applied potential range ±10V, current ±1A. Comprehensive techniques: Built-in EIS (10μHz~1MHz) is equipped.
Bipotentiostat
2 Channel Bipotentiostat
TOB-CS-2350 bipotentiostat is developed from single channel TOB-CS-350 potentiostat/galvanostat. There are two s ets of built-in potentiostat /galvanostat. The two channels can conduct same or different experiments ind ependently/simultaneously.
Multichannel Potentiostat
Multichannel Potentiostat Galvanostat EIS
This TOB-CS310X multichannel potentiostat galvanostat EIS is a versatile instrument offering 8 slots.
Nickel Mesh
0.05mm Nickel Mesh For Lithium Battery Substrate
0.05mm Nickel Mesh For Lithium Battery Substrate.
Eyelet machine
Supercapacitor Tab Eyelet Machine
The device is suitable for the punching and trimming operation of quadrate supercapacitor and lithium ion power battery tab.
LiMn2O4 powder supplier
High quanlity LiMn2O4 powder supplier
High quanlity LiMn2O4 powder use for lithium battery cathode materials.
Battery Anode Materials
Battery Anode Active Materials Graphite MCMB LTO Silicon Anode Powder Large Quantity Order
TOB New Energy provides large batch order of the lithium-ion battery, sodium ion battery and supercapacitor anode materials, such as graphite, MCMB, LTO, Silicon anode, soft carbon, hard carbon, etc.
Box Furnace
Intelligent Lab Chamber Furnace
1800 degree Intelligent Lab Chamber Furnace This furnace has the advantages of balanced temperature field, low surface temperature, fast temperature rise and fall rate, and energy conservation. It is a special and ideal equipment developed for high-temperature sintering, high-temperature annealing, melting, and analysis in universities, research institutions, and industrial and mining enterprises.

leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

Company

top